ATV312HU40N4
-
Product is not available
Minimum Order Quantity1
Accept Small Orders No
-
Additional Information
Main range of product product or component type product destination product specific application assembly style component name motor power kW motor power hp [Us] rated supply voltage supply frequency network number of phases line current EMC filter apparent power maximum transient current power dissipation in W speed range asynchronous motor control profile electrical connection supply communication port protocol IP degree of protection option card
Altivar 312
Variable speed drive
Asynchronous motors
Simple machine
With heat sink
ATV312
4 kW
5 hp
380...500 V - 15...10 %
50...60 Hz - 5...5 %
3 phases
13.9 A at 380 V, Isc = 5 kA
10.6 A at 500 V
Integrated
9.2 kVA
14.3 A for 60 s
150 W at nominal load
1…50
Sensorless flux vector control with PWM type motor control signal
Factory set : constant torque
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 2.5 mm² AWG 14
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 5 mm² AWG 10
Internal supply for logic inputs: 19...30 V 100 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (2.2 to 10 kOhm): 10...10.8 V 10 mA, protection type: overload and short-circuit protection
Modbus
CANopen
IP20 on upper part without cover plate
IP21 on connection terminals
IP31 on upper part
IP41 on upper part
Communication card for CANopen daisy chain
Communication card for DeviceNet
Communication card for Fipio
Communication card for Modbus TCP
Communication card for Profibus DP
Complementary supply voltage limits prospective line Isc continuous output current output frequency nominal switching frequency switching frequency transient overtorque braking torque regulation loop motor slip compensation output voltage discrete output number discrete output type minimum switching current maximum switching current discrete input number discrete input type acceleration and deceleration ramps braking to standstill protection type insulation resistance local signalling time constant frequency resolution connector type physical interface transmission frame transmission rate number of addresses number of drive marking operating position outer dimension height width depth net weight
323…550 V
5 kA
9.5 A at 4 kHz
0…500 kHz
4 kHz
2...16 kHz adjustable
170…200 % of nominal motor torque
150 % during 60 s with braking resistor
100 % with braking resistor continuously
150 % without braking resistor
Frequency PI regulator
Suppressable
Automatic whatever the load
Adjustable
19 V (state 0)
Positive logic (source) (LI1...LI6), < 5 V (state 0), > 11 V (state 1)
2
Configurable relay logic: (R1A, R1B, R1C) 1 NO + 1 NC - 100000 cycles
Configurable relay logic: (R2A, R2B) NC - 100000 cycles
R1-R2 10 mA at 5 V DC
R1-R2: 2 A at 250 V AC inductive load, cos phi = 0.4 and L/R = 7 ms
R1-R2: 2 A at 30 V DC inductive load, cos phi = 0.4 and L/R = 7 ms
R1-R2: 5 A at 250 V AC resistive load, cos phi = 1 and L/R = 0 ms
R1-R2: 5 A at 30 V DC resistive load, cos phi = 1 and L/R = 0 ms
6
(LI1...LI6) programmable at 24 V, 0…100 mA for PLC, impedance: 3500 Ohm
S, U or customized
Linear adjustable separately from 0.1 to 999.9 s
By DC injection
Input phase breaks: drive
Line supply overvoltage and undervoltage safety circuits: drive
Line supply phase loss safety function, for three phases supply: drive
Motor phase breaks: drive
Overcurrent between output phases and earth (on power up only): drive
Overheating protection: drive
Short-circuit between motor phases: drive
Thermal protection: motor
>= 500 mOhm 500 V DC for 1 minute
1 LED (red)drive voltage:
Four 7-segment display unitsCANopen bus status:
5 ms for reference change
Analog input: 0.1...100 Hz
Display unit: 0.1 Hz
1 RJ45 for Modbus/CANopen
RS485 multidrop serial link
RTU
10, 20, 50, 125, 250, 500 kbps or 1 Mbps for CANopen
4800, 9600 or 19200 bps for Modbus
1…127 for CANopen
1…247 for Modbus
127 for CANopen
31 for Modbus
CE
Vertical +/- 10 degree
215 x 185 x 158 mm
184 x 140 x 150 mm
402 x 239 x 192 mm
184 mm
142 mm
152 mm
3.1 kg
Environment dielectric strength electromagnetic compatibility standards product certifications pollution degree protective treatment vibration resistance shock resistance relative humidity ambient air temperature for storage ambient air temperature for operation operating altitude
2410 V DC between earth and power terminals
3400 V AC between control and power terminals
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
IEC 61800-3
IEC 61800-5-1
CSA
C-Tick
DNV
NOM
GOST
UL
2
TC
1 gn (f= 13…150 Hz) conforming to EN/IEC 60068-2-6
1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6
15 gn for 11 ms conforming to EN/IEC 60068-2-27
5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
-25…70 °C
-10…50 °C without derating (with protective cover on top of the drive)
-10…60 °C with derating factor (without protective cover on top of the drive) -