ATV320U04M2C

SKU:ATV320U04M2C

Price upon request
  • Product is not available

-
+

Minimum Order Quantity1

Accept Small Orders No

Variable speed drive, ATV320, 0.37 kW, 200…240 V, 1 phase, compact
  • Additional Information

    Complementary
    number of HW interfaces other
    1.0
     
    nominal output power
    0.37 W
     
    number of HW interfaces serial RS232
    0.0
     
    number of HW interfaces serial RS422
    0.0
     
    number of HW interfaces serial RS485
    1.0
     
    number of HW interfaces serial TTY
    0.0
     
    number of HW interfaces USB
    0.0
     
    [Us] rated supply voltage
    200...240 V - 15...10 %
     
    number of HW interfaces industrial Ethernet
    0.0
     
    number of HW interfaces parallel
    0.0
     
    number of HW interfaces PROFINET
    0.0
     
    range of product
    Altivar Machine ATV320
     
    line current
    5.9 A at 200 V (heavy duty)
    4.9 A at 240 V (heavy duty)
     
    product or component type
    Variable speed drive
     
    prospective line Isc
    1 kA
     
    product specific application
    Complex machines
     
    device short name
    ATV320
     
    variant
    Standard version
     
    format of the control block
    Compact
     
    continuous output current
    3.3 A at 4 kHz for heavy duty
     
    product destination
    Synchronous motors
    Asynchronous motors
     
    EMC filter
    Class C2 EMC filter integrated
     
    IP degree of protection
    IP20 conforming to IEC 61800-5-1
    IP20 conforming to IEC 60529
     
    power range
    0.37...0.55 kW at 200…240 V, 1 phase (based on load duty)
     
    asynchronous motor control profile
    Voltage/frequency ratio, 5 points
    Flux vector control without sensor, standard
    Voltage/frequency ratio - Energy Saving, quadratic U/f
    Flux vector control without sensor - Energy Saving
    Voltage/frequency ratio, 2 points
     
    degree of protection
    UL type 1 conforming to UL 61800-5-1 (with conformity kit)
     
    synchronous motor control profile
    Vector control without sensor
     
    type of cooling
    Fanless
     
    speed drive output frequency
    0.1…599 Hz
     
    network number of phases
    1 phase
     
    nominal switching frequency
    4 kHz
     
    supply frequency
    50...60 Hz - 5...5 %
     
    switching frequency
    2...16 kHz adjustable
    4...16 kHz with derating factor
     
    motor power kW
    0.37 kW for heavy duty
     
    motor power hp
    0.5 hp for heavy duty
     
    communication port protocol
    Modbus serial
    CANopen
     
    apparent power
    1.2 kVA at 240 V (heavy duty)
     
    output voltage
    <= power supply voltage
     
    maximum transient current
    5.0 A during 60 s (heavy duty)
     
    permissible temporary current boost
    1.5 x In during 60 s (heavy duty)
     
    speed range
    1…100 for asynchronous motor in open-loop mode
     
    speed accuracy
    +/- 10 % of nominal slip 0.2 Tn to Tn
     
    torque accuracy
    +/- 15 %
     
    transient overtorque
    170…200 % of nominal motor torque
     
    braking torque
    <= 170 % during 60 s with braking resistor
     
    safety function
    STO (safe torque off) SIL 3
    SLS (safe limited speed)
    SS1 (safe stop 1)
    SMS (safe maximum speed)
    GDL (guard door locking)
     
    regulation loop
    Adjustable PID regulator
     
    motor slip compensation
    Automatic whatever the load
    Adjustable 0...300 %
    Not available in voltage/frequency ratio (2 or 5 points)
     
    optional communication modules
    Communication module, CANopen daisy chain RJ45
    Communication module, CANopen SUB-D 9
    Communication module, CANopen open style terminal block
    Communication module, EtherCAT RJ45
    Communication module, DeviceNet
    Communication module, Ethernet/IP
    Communication module, Profibus DP V1
    Communication module, Profinet
    Communication module, Ethernet Powerlink
     
    acceleration and deceleration ramps
    Linear
    U
    S
    CUS
    Ramp switching
    Acceleration/deceleration ramp adaptation
    Acceleration/deceleration automatic stop with DC injection
     
    braking to standstill
    By DC injection
     
    protection type
    Input phase breaks: drive
    Overcurrent between output phases and earth: drive
    Overheating protection: drive
    Short-circuit between motor phases: drive
    Thermal protection: drive
     
    frequency resolution
    Display unit: 0.1 Hz
    Analog input: 0.012/50 Hz
     
    electrical connection
    Screw terminal, clamping capacity: 2.5...4 mm², AWG 14...AWG 12 (power supply)
    Screw terminal, clamping capacity: 2.5...4 mm², AWG 14...AWG 12 (DC bus)
    Screw terminal, clamping capacity: 2.5...4 mm², AWG 14...AWG 12 (motor/braking resistor)
    Screw terminal, clamping capacity: 0.5...1.5 mm², AWG 20...AWG 16 (control)
     
    connector type
    1 RJ45 (on terminal) for Modbus/CANopen
     
    physical interface
    2-wire RS 485 for Modbus serial/CANopen
     
    transmission frame
    RTU for Modbus serial
     
    transmission rate
    4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen
     
    data format
    8 bits, configurable odd, even or no parity for Modbus serial
     
    type of polarization
    No impedance for Modbus serial
     
    number of addresses
    1…127 for CANopen
    1…247 for Modbus serial
     
    method of access
    Slave CANopen
     
    supply
    Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
     
    local signalling
    1 LED (green)CANopen run:
    1 LED (red)CANopen error:
    1 LED (red)drive fault:
     
    width
    72.0 mm
     
    height
    143.0 mm
     
    depth
    128.0 mm
     
    net weight
    1.0 kg
     
    analogue input number
    3
     
    analogue input type
    AI1 voltage: 0...10 V DC, impedance: 30000 Ohm, resolution 10 bits
    AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30000 Ohm, resolution 10 bits
    AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits
     
    discrete input number
    7
     
    discrete input type
    Programmable (sink/source) (DI1...DI4)24...30 V DC, with level 1 PLC
    Programmable as pulse input 20 kpps (DI5)24...30 V DC, with level 1 PLC
    Switch-configurable PTC probe (DI6)24...30 V DC
    Safe torque off (STO)24...30 V DC - 1500 Ohm
     
    discrete input logic
    Negative logic (sink) (DI1...DI6), > 19 V (state 0), < 13 V (state 1)
    Positive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1)
     
    analogue output number
    1
     
    analogue output type
    AQ1 software-configurable current: 0...20 mA, impedance: 800 Ohm, resolution 10 bits
    AQ1 software-configurable voltage: 0...10 V, impedance: 470 Ohm, resolution 10 bits
     
    sampling duration
    2 ms (AI1, AI2, AI3) - analog input
    2 ms (AQ1) - analog output
     
    accuracy
    +/- 0.2 % AI1, AI2, AI3 for a temperature of -10...60 °C analog input
    +/- 0.5 % AI1, AI2, AI3 for a temperature of 25 °C analog input
    +/- 1 % AQ1 for a temperature of 25 °C analog output
    +/- 2 % AQ1 for a temperature of -10...60 °C analog output
     
    linearity error
    AI1, AI2, AI3: +/- 0.2...0.5 % of maximum value for analog input
    AQ1: +/- 0.3 % for analog output
     
    discrete output number
    3
     
    discrete output type
    Configurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles
    Configurable relay logic: (R2A, R2B) NO - 100000 cycles
    Logic: (LO)
     
    refresh time
    Logic input (DI1...DI6): 8 ms (+/- 0.7 ms)
    Relay output (R1A, R1B, R1C): 2 ms
    Relay output (R2A, R2C): 2 ms
     
    minimum switching current
    Relay output R1, R2: 5 mA at 24 V DC
     
    maximum switching current
    Relay output R1 on resistive load, cos phi = 1: 3 A at 250 V AC
    Relay output R1 on resistive load, cos phi = 1: 4 A at 30 V DC
    Relay output R1, R2 on inductive load, cos phi = 0.4: 2 A at 250 V AC
    Relay output R1, R2 on inductive load, cos phi = 0.4: 2 A at 30 V DC
    Relay output R2 on resistive load, cos phi = 1: 5 A at 250 V AC
    Relay output R2 on resistive load, cos phi = 1: 5 A at 30 V DC
     
    isolation
    Between power and control terminals
     
    insulation resistance
    > 1 MOhm 500 V DC for 1 minute to earth
     
    noise level
    0.0 dB conforming to 86/188/EEC
     
    power dissipation in W
    Self-cooled: 30.0 W at 200 V, switching frequency 4 kHz
     
    operating position
    Vertical +/- 10 degree
     
    operating altitude
    <= 1000 m without derating
    1000...2000 m with current derating 1 % per 100 m
     
    standards
    EN/IEC 61800-3
    Environment 1 category C2 EN/IEC 61800-3
    Environment 2 category C3 EN/IEC 61800-3
    EN/IEC 61800-5-1
    IEC 60721-3
    IEC 61508
    IEC 13849-1
    UL 508C
    UL 61800-5-1
    CSA C22.2 No 274
     
    product certifications
    CE
    ATEX
    NOM
    GOST
    EAC
    RCM
    KC
    REACH
     
    marking
    CE
    ATEX
    UL
    CSA
    EAC
    RCM
     
    Environment
    electromagnetic compatibility
    Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
    1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
    Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
     
    pollution degree
    2 conforming to EN/IEC 61800-5-1
     
    vibration resistance
    1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6
    1.5 mm peak to peak (f= 2…13 Hz) conforming to EN/IEC 60068-2-6
     
    shock resistance
    15 gn for 11 ms conforming to EN/IEC 60068-2-27
     
    relative humidity
    5…95 % without condensation conforming to IEC 60068-2-3
    5…95 % without dripping water conforming to IEC 60068-2-3
     
    ambient air temperature for operation
    -10…50 °C without derating
    50…60 °C with derating factor
     
    ambient air temperature for storage
    -25…70 °C
     
    environmental characteristic
    Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
    Dust pollution resistance class 3S2 conforming to EN/IEC 60721-3-3
     
    Packing Units
    Unit Type of Package 1
    PCE
     
    Number of Units in Package 1
    1
     
    Package 1 Weight
    1.181 kg
     
    Package 1 Height
    11.5 cm
     
    Package 1 width
    18.7 cm
     
    Package 1 Length
    19 cm
     
    Unit Type of Package 2
    P06
     
    Number of Units in Package 2
    45
     
    Package 2 Weight
    66.15 kg
     
    Package 2 Height
    80 cm
     
    Package 2 width
    80 cm
     
    Package 2 Length
    60 cm
     
    Offer Sustainability
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
     
    Mercury free
    Yes
     
    RoHS exemption information  
    China RoHS Regulation  
    Environmental Disclosure  
    Circularity Profile  
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

  • Reviews ()

    Write a Review