ATV320U75M3C

SKU:ATV320U75M3C

Price upon request
  • Product is not available

-
+

Minimum Order Quantity1

Accept Small Orders No

Variable speed drive, ATV320, 7.5 kW, 200…240 V, 3 phases, compact
  • Additional Information

    Complementary
    [Us] rated supply voltage
    200...240 V - 15...10 %
     
    supply voltage limits
    170…264 V
     
    mounting mode
    Internal mounting
     
    relative symmetric mains voltage tolerance
    10 %
     
    maximum output voltage
    240.0 V
     
    range of product
    Altivar Machine ATV320
     
    product or component type
    Variable speed drive
     
    network frequency
    50...60 Hz
     
    prospective line Isc
    22 kA
     
    product specific application
    Complex machines
     
    relative symmetric network frequency tolerance
    5 %
     
    variant
    Standard version
     
    continuous output current
    33.0 A at 4 kHz for heavy duty
     
    EMC filter
    Without EMC filter
     
    4 quadrant operation possible
    True
     
    asynchronous motor control profile
    Voltage/frequency ratio, 5 points
    Flux vector control without sensor, standard
    Voltage/frequency ratio - Energy Saving, quadratic U/f
    Flux vector control without sensor - Energy Saving
    Voltage/frequency ratio, 2 points
     
    synchronous motor control profile
    Vector control without sensor
     
    type of cooling
    Fan
     
    speed drive output frequency
    0.1…599 Hz
     
    network number of phases
    3 phases
     
    nominal switching frequency
    4 kHz
     
    supply frequency
    50...60 Hz - 5...5 %
     
    switching frequency
    2...16 kHz adjustable
    4...16 kHz with derating factor
     
    motor power kW
    7.5 kW for heavy duty
     
    brake chopper integrated
    True
     
    communication port protocol
    Modbus serial
    CANopen
     
    application in industrial area permitted
    True
     
    apparent power
    15.9 kVA at 240 V (heavy duty)
     
    output voltage
    <= power supply voltage
     
    overvoltage category
    III
     
    regulation loop
    Adjustable PID regulator
     
    motor slip compensation
    Automatic whatever the load
    Adjustable 0...300 %
    Not available in voltage/frequency ratio (2 or 5 points)
     
    acceleration and deceleration ramps
    Linear
    U
    S
    CUS
    Ramp switching
    Acceleration/deceleration ramp adaptation
    Acceleration/deceleration automatic stop with DC injection
     
    braking to standstill
    By DC injection
     
    protection type
    Input phase breaks: drive
    Overcurrent between output phases and earth: drive
    Overheating protection: drive
    Short-circuit between motor phases: drive
    Thermal protection: drive
     
    frequency resolution
    Display unit: 0.1 Hz
    Analog input: 0.012/50 Hz
     
    method of access
    Slave CANopen
     
    width
    150.0 mm
     
    depth
    178.0 mm
     
    net weight
    3.6 kg
     
    analogue input number
    3
     
    discrete input number
    7
     
    analogue output number
    1
     
    sampling duration
    2 ms (AI1, AI2, AI3) - analog input
    2 ms (AQ1) - analog output
     
    accuracy
    +/- 0.2 % AI1, AI2, AI3 for a temperature of -10...60 °C analog input
    +/- 0.5 % AI1, AI2, AI3 for a temperature of 25 °C analog input
    +/- 1 % AQ1 for a temperature of 25 °C analog output
    +/- 2 % AQ1 for a temperature of -10...60 °C analog output
     
    linearity error
    AI1, AI2, AI3: +/- 0.2...0.5 % of maximum value for analog input
    AQ1: +/- 0.3 % for analog output
     
    with safety function Safe torque off (STO)
    True
     
    discrete output number
    3
     
    discrete output type
    Configurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles
    Configurable relay logic: (R2A, R2B) NO - 100000 cycles
    Logic: (LO)
     
    with safety function Safe Stop 1 (SS1)
    True
     
    refresh time
    Logic input (DI1...DI6): 8 ms (+/- 0.7 ms)
    Relay output (R1A, R1B, R1C): 2 ms
    Relay output (R2A, R2C): 2 ms
     
    with sft fct Safe Stop 2 (SS2)
    False
     
    minimum switching current
    Relay output R1, R2: 5 mA at 24 V DC
     
    with safety function Safe Operating Stop (SOS)
    False
     
    maximum switching current
    Relay output R1 on resistive load, cos phi = 1: 3 A at 250 V AC
    Relay output R1 on resistive load, cos phi = 1: 4 A at 30 V DC
    Relay output R1, R2 on inductive load, cos phi = 0.4: 2 A at 250 V AC
    Relay output R1, R2 on inductive load, cos phi = 0.4: 2 A at 30 V DC
    Relay output R2 on resistive load, cos phi = 1: 5 A at 250 V AC
    Relay output R2 on resistive load, cos phi = 1: 5 A at 30 V DC
     
    with safety function Safe brake management (SBC/SBT)
    False
     
    with safety function Safely Limited Speed (SLS)
    True
     
    isolation
    Between power and control terminals
     
    insulation resistance
    > 1 MOhm 500 V DC for 1 minute to earth
     
    with safety function Safe Speed Monitor (SSM)
    False
     
    with safety function Safe Direction (SDI)
    False
     
    power dissipation in W
    Fan: 293.0 W at 200 V, switching frequency 4 kHz
     
    with safety function Safely Limited Position (SLP)
    False
     
    with safety function Safe Position (SP)
    False
     
    volume of cooling air
    60.0 m3/h
     
    with safety function Safe programmable logic
    False
     
    operating position
    Vertical +/- 10 degree
     
    ambient air transport temperature
    -25…70 °C
     
    product certifications
    CE
    ATEX
    NOM
    GOST
    EAC
    RCM
    KC
    REACH
     
    marking
    CE
    ATEX
    UL
    CSA
    EAC
    RCM
     
    Environment
    electromagnetic compatibility
    Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
    1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
    Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
     
    vibration resistance
    1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6
    1.5 mm peak to peak (f= 2…13 Hz) conforming to EN/IEC 60068-2-6
     
    shock resistance
    15 gn for 11 ms conforming to EN/IEC 60068-2-27
     
    relative humidity
    5…95 % without condensation conforming to IEC 60068-2-3
    5…95 % without dripping water conforming to IEC 60068-2-3
     
    ambient air temperature for operation
    -10…50 °C without derating
    50…60 °C with derating factor
     
    ambient air temperature for storage
    -25…70 °C
     
    environmental characteristic
    Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
    Dust pollution resistance class 3S2 conforming to EN/IEC 60721-3-3
     
    Packing Units
    Unit Type of Package 1
    PCE
     
    Number of Units in Package 1
    1
     
    Package 1 Weight
    4.351 kg
     
    Package 1 Height
    19.5 cm
     
    Package 1 width
    22 cm
     
    Package 1 Length
    33 cm
     
    Unit Type of Package 2
    P06
     
    Number of Units in Package 2
    10
     
    Package 2 Weight
    56.51 kg
     
    Package 2 Height
    80 cm
     
    Package 2 width
    80 cm
     
    Package 2 Length
    60 cm
     
    Offer Sustainability
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
     
    Mercury free
    Yes
     
    RoHS exemption information  
    China RoHS Regulation  
    Environmental Disclosure  
    Circularity Profile  
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

  • Reviews ()