ATV32HU22M2
Price upon request
-
Product is not available
Minimum Order Quantity1
Accept Small Orders No
Variable speed drive ATV32 - 2.2 kw - 200 V - 1 phase - with heat sink
-
Additional Information
Main range of product Altivar 32product or component type Variable speed driveproduct destination Synchronous motors
Asynchronous motorsproduct specific application Complex machinesfunction available -assembly style With heat sinkcomponent name ATV32EMC filter Class C2 EMC filter integratednetwork number of phases 1 phase[Us] rated supply voltage 200...240 V - 15...10 %supply voltage limits 170…264 Vsupply frequency 50...60 Hz - 5...5 %network frequency 47.5...63 Hzmotor power kW 2.2 kW at 200...240 Vmotor power hp 3 hp at 200...240 VComplementary line current 20.1 A for 240 V 1 phase 2.2 kW / 3 hp
23.9 A for 200 V 1 phase 2.2 kW / 3 hpapparent power 4.8 kVA at 240 V 1 phase 2.2 kW / 3 hpprospective line Isc 1 kA for 1 phasenominal output current 11 A at 4 kHz 240 V 2.2 kW / 3 hpmaximum transient current 16.5 A for 60 s 2.2 kW / 3 hpoutput frequency 0.0005…0.599 kHznominal switching frequency 4 kHzswitching frequency 2...16 kHz adjustablespeed range 1…100 for asynchronous motor in open-loop modespeed accuracy +/- 10 % of nominal slip 0.2 Tn to Tntorque accuracy +/- 15 %transient overtorque 170…200 %braking torque <= 170 % with braking resistorasynchronous motor control profile Voltage/frequency ratio, 5 points
Voltage/frequency ratio - Energy Saving, quadratic U/f
Flux vector control without sensor - Energy Saving, NoLoad law
Flux vector control without sensor, standard
Voltage/frequency ratio, 2 pointssynchronous motor control profile Vector control without sensorregulation loop Adjustable PID regulatormotor slip compensation Automatic whatever the load
Not available in voltage/frequency ratio (2 or 5 points)
Adjustable 0...300 %local signalling 1 LED red for drive voltage
1 LED green for CANopen run
1 LED red for CANopen error
1 LED red for drive faultoutput voltage <= power supply voltagenoise level 43 dB conforming to 86/188/EECinsulation Electrical between power and controlelectrical connection Screw terminal, clamping capacity: 4 mm², AWG 10 (power supply)
Screw terminal, clamping capacity: 0.5...1.5 mm², AWG 18...AWG 14 (control)
Removable screw terminals, clamping capacity: 1.5...2.5 mm², AWG 14...AWG 12 (motor/braking resistor)tightening torque 0.5 N.m, 4.4 lb/ft (control)
0.7 N.m, 7.1 lb/ft (motor/braking resistor)
0.6 N.m, 5.3 lb/ft (power supply)supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protectionanalogue input number 3analogue input type AI1 voltage: 0...10 V DC, impedance: 30000 Ohm, resolution 10 bits
AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30000 Ohm, resolution 10 bits
AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bitssampling duration 2 ms (AI1, AI2, AI3) - analog input(s)
2 ms (AO1) - analog input(s)response time LI1...LI6 8 ms, tolerance +/- 0.7 ms for logic output(s)
R1A, R1B, R1C 2 ms for relay output(s)
R2A, R2C 2 ms for relay output(s)accuracy +/- 0.2 % (AI1, AI2, AI3) for a temperature of -10...60 °C
+/- 0.5 % (AI1, AI2, AI3) for a temperature of 25 °C
+/- 1 % (AO1) for a temperature of 25 °C
+/- 2 % (AO1) for a temperature of -10...60 °Clinearity error +/- 0.2...0.5 % of maximum value (AI1, AI2, AI3)
+/- 0.3 % (AO1)analogue output number 1analogue output type AO1 software-configurable current 0...20 mA, impedance: 800 Ohm, resolution 10 bits
AO1 software-configurable voltage 0...10 V, impedance: 470 Ohm, resolution 10 bitsdiscrete output number 3discrete output type Configurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles
Configurable relay logic: (R2A, R2B) NO - 100000 cycles
Logic: (LO)minimum switching current 5 mA at 24 V DC for configurable relay logicmaximum switching current R1: 3 A at 250 V AC resistive load, cos phi = 1
R1: 4 A at 30 V DC resistive load, cos phi = 1
R1, R2: 2 A at 250 V AC inductive load, cos phi = 0.4
R1, R2: 2 A at 30 V DC inductive load, cos phi = 0.4
R2: 5 A at 250 V AC resistive load, cos phi = 1
R2: 5 A at 30 V DC resistive load, cos phi = 1discrete input number 7discrete input type Programmable (sink/source) (LI1...LI4)24...30 V DC, with level 1 PLC
Programmable as pulse input 20 kpps (LI5)24...30 V DC, with level 1 PLC
Switch-configurable PTC probe (LI6)24...30 V DC
Safe torque off (STO)24...30 V DC - 1500 Ohmdiscrete input logic Negative logic (sink) (LI1...LI6), > 19 V (state 0), < 13 V (state 1)
Positive logic (source) (LI1...LI6), < 5 V (state 0), > 11 V (state 1)acceleration and deceleration ramps U
Ramp switching
Deceleration ramp automatic stop DC injection
S
CUS
Deceleration ramp adaptation
Linearbraking to standstill By DC injectionprotection type Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overheating protection: drive
Short-circuit between motor phases: drive
Thermal protection: drivecommunication port protocol Modbus
CANopenconnector type 1 RJ45 (on front face) for Modbus/CANopenphysical interface 2-wire RS 485 for Modbustransmission frame RTU for Modbustype of polarization No impedance for Modbusnumber of addresses 1…127 for CANopen
1…247 for Modbusmethod of access Slave CANopenelectromagnetic compatibility 1.2/50 µs - 8/20 µs surge immunity test, level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test, level 3 conforming to IEC 61000-4-6
Electrical fast transient/burst immunity test, level 4 conforming to IEC 61000-4-4
Electrostatic discharge immunity test, level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test, level 3 conforming to IEC 61000-4-3
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11width 60 mmheight 325 mmdepth 245 mmnet weight 2.9 kgoption card Communication card for CANopen daisy chain
Communication card for CANopen open style
Communication card for DeviceNet
Communication card for Ethernet/IP
Communication card for Profibus DP V1Environment standards EN/IEC 61800-3
EN 61800-3 environments 2 category C2
EN 55011 class A group 1
EN/IEC 61800-5-1
EN 61800-3 environments 1 category C2product certifications C-Tick
NOM 117
UL
CSA
GOSTmarking CEpollution degree 2 conforming to EN/IEC 61800-5-1IP degree of protection IP20 conforming to EN/IEC 61800-5-1vibration resistance 1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f = 3…13 Hz) conforming to EN/IEC 60068-2-6shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3ambient air temperature for operation -10…50 °C without derating
50…60 °C with derating factorambient air temperature for storage -25…70 °Coperating altitude <= 1000 m without derating
1000...2000 m with current derating 1 % per 100 moperating position Vertical +/- 10 degreePacking Units Package 1 Weight 2.713 kgPackage 1 Height 1.000 dmPackage 1 width 2.750 dmPackage 1 Length 3.250 dmContractual warranty Warranty 18 months -