ATV630D11M3

SKU:ATV630D11M3

Price upon request
  • Product is not available

-
+

Minimum Order Quantity1

Accept Small Orders No

Variable speed drive ATV630, 11kW/15HP, 200...240V, IP21/UL type 1
  • Additional Information

    Main
    range of product
    Altivar Process ATV600
     
    product or component type
    Variable speed drive
     
    product specific application
    Process and utilities
     
    device short name
    ATV630
     
    variant
    Standard version
     
    product destination
    Synchronous motors
    Asynchronous motors
     
    EMC filter
    Without EMC filter
     
    IP degree of protection
    IP21 conforming to IEC 61800-5-1
    IP21 conforming to IEC 60529
     
    degree of protection
    UL type 1 conforming to UL 508C
     
    type of cooling
    Forced convection
     
    supply frequency
    50...60 Hz - 5...5 %
     
    network number of phases
    3 phases
     
    [Us] rated supply voltage
    200...240 V - 15...10 %
     
    motor power kW
    11 kW (normal duty)
    7.5 kW (heavy duty)
     
    motor power hp
    15 hp normal duty
    10 hp heavy duty
     
    line current
    39.3 A at 200 V (normal duty)
    32.9 A at 240 V (normal duty)
    27.2 A at 200 V (heavy duty)
    23.1 A at 240 V (heavy duty)
     
    prospective line Isc
    50 kA
     
    apparent power
    13.7 kVA at 240 V (normal duty)
    9.6 kVA at 240 V (heavy duty)
     
    continuous output current
    46.8 A at 4 kHz for normal duty
    32.7 A at 4 kHz for heavy duty
     
    maximum transient current
    51.5 A during 60 s (normal duty)
    49.1 A during 60 s (heavy duty)
     
    asynchronous motor control profile
    Optimized torque mode
    Variable torque standard
    Constant torque standard
     
    synchronous motor control profile
    Permanent magnet motor
    Synchronous reluctance motor
     
    output frequency
    0.0001…0.5 kHz
     
    speed drive output frequency
    0.1…599 Hz
     
    nominal switching frequency
    4 kHz
     
    switching frequency
    2...12 kHz adjustable
    4...12 kHz with derating factor
     
    safety function
    STO (safe torque off) SIL 3
     
    discrete input logic
    16 preset speeds
     
    communication port protocol
    Ethernet
    Modbus serial
    Modbus TCP
     
    option card
    Slot A: communication module, Profibus DP V1
    Slot A: communication module, Profinet
    Slot A: communication module, DeviceNet
    Slot A: communication module, Modbus TCP/EtherNet/IP
    Slot A: communication module, CANopen daisy chain RJ45
    Slot A: communication module, CANopen SUB-D 9
    Slot A: communication module, CANopen screw terminals
    Slot A/slot B: digital and analog I/O extension module
    Slot A/slot B: output relay extension module
    Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link
    Communication module, BACnet MS/TP
    Communication module, Ethernet Powerlink
     
    Complementary
    output voltage
    <= power supply voltage
     
    permissible temporary current boost
    1.1 x In during 60 s (normal duty)
    1.5 x In during 60 s (heavy duty)
     
    motor slip compensation
    Can be suppressed
    Not available in permanent magnet motor law
    Automatic whatever the load
    Adjustable
     
    acceleration and deceleration ramps
    Linear adjustable separately from 0.01...9999 s
     
    braking to standstill
    By DC injection
     
    protection type
    Thermal protection: motor
    Safe torque off: motor
    Motor phase break: motor
    Thermal protection: drive
    Safe torque off: drive
    Overheating: drive
    Overcurrent between output phases and earth: drive
    Overload of output voltage: drive
    Short-circuit protection: drive
    Motor phase break: drive
    Overvoltages on the DC bus: drive
    Line supply overvoltage: drive
    Line supply undervoltage: drive
    Line supply phase loss: drive
    Overspeed: drive
    Break on the control circuit: drive
     
    frequency resolution
    Display unit: 0.1 Hz
    Analog input: 0.012/50 Hz
     
    electrical connection
    Control: removable screw terminals0.5...1.5 mm²/AWG 20...AWG 16
    Motor: screw terminal16 mm²/AWG 6
    Line side: screw terminal10...16 mm²/AWG 8...AWG 6
     
    connector type
    RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
    RJ45 (on the remote graphic terminal) for Modbus serial
     
    physical interface
    2-wire RS 485 for Modbus serial
     
    transmission frame
    RTU for Modbus serial
     
    transmission rate
    10/100 Mbit/s for Ethernet IP/Modbus TCP
    4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
     
    exchange mode
    Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
     
    data format
    8 bits, configurable odd, even or no parity for Modbus serial
     
    type of polarization
    No impedance for Modbus serial
     
    number of addresses
    1…247 for Modbus serial
     
    method of access
    Slave Modbus TCP
     
    supply
    External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
    Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
     
    local signalling
    3 LEDslocal diagnostic:
    3 LEDs (dual colour)embedded communication status:
    4 LEDs (dual colour)communication module status:
    1 LED (red)presence of voltage:
     
    width
    211 mm
     
    height
    546 mm
     
    depth
    232 mm
     
    net weight
    13.8 kg
     
    analogue input number
    3
     
    analogue input type
    AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
    AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits
     
    discrete input number
    8
     
    discrete input type
    DI1...DI6 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm
    DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm
     
    input compatibility
    DI1...DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2
    DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68
    STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
     
    discrete input logic
    Positive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1)
    Negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1)
    Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1)
    Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
     
    analogue output number
    2
     
    analogue output type
    Software-configurable voltage AO1, AO2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
    Software-configurable current AO1, AO2: 0...20 mA, resolution 10 bits
     
    sampling duration
    2 ms +/- 0.5 ms (DI1...DI4) - discrete input
    5 ms +/- 1 ms (DI5, DI6) - discrete input
    5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input
    10 ms +/- 1 ms (AO1) - analog output
     
    accuracy
    +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
    +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
     
    linearity error
    AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
    AO1, AO2: +/- 0.2 % for analog output
     
    relay output number
    3
     
    relay output type
    Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
    Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
    Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
     
    refresh time
    Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
     
    minimum switching current
    Relay output R1, R2, R3: 5 mA at 24 V DC
     
    maximum switching current
    Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
    Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
    Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
    Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
     
    isolation
    Between power and control terminals
     
    Variable speed drive application selection
    Building - HVAC Compressor centrifugal
    Food and beverage processing Other application
    Mining mineral and metal Fan
    Mining mineral and metal Pump
    Oil and gas Fan
    Water and waste water Other application
    Building - HVAC Screw compressor
    Food and beverage processing Pump
    Food and beverage processing Fan
    Food and beverage processing Atomization
    Oil and gas Electro submersible pump (ESP)
    Oil and gas Water injection pump
    Oil and gas Jet fuel pump
    Oil and gas Compressor for refinery
    Water and waste water Centrifuge pump
    Water and waste water Positive displacement pump
    Water and waste water Electro submersible pump (ESP)
    Water and waste water Screw pump
    Water and waste water Lobe compressor
    Water and waste water Screw compressor
    Water and waste water Compressor centrifugal
    Water and waste water Fan
    Water and waste water Conveyor
    Water and waste water Mixer
     
    Motor power range AC-3
    7…11 kW at 200…240 V 3 phases
     
    mounting mode
    Wall mount
     
    Environment
    insulation resistance
    > 1 MOhm 500 V DC for 1 minute to earth
     
    noise level
    59.5 dB conforming to 86/188/EEC
     
    power dissipation in W
    Natural convection: 62 W at 200 V, switching frequency 4 kHz
    Forced convection: 452 W at 200 V, switching frequency 4 kHz
     
    volume of cooling air
    215 m3/h
     
    operating position
    Vertical +/- 10 degree
     
    maximum THDI
    <48 % from 80...100 % of load conforming to IEC 61000-3-12
     
    electromagnetic compatibility
    Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
    1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
    Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
     
    pollution degree
    2 conforming to EN/IEC 61800-5-1
     
    vibration resistance
    1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
    1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
     
    shock resistance
    15 gn for 11 ms conforming to IEC 60068-2-27
     
    relative humidity
    5…95 % without condensation conforming to IEC 60068-2-3
     
    ambient air temperature for operation
    -15…50 °C (without derating)
    50…60 °C (with derating factor)
     
    ambient air temperature for storage
    -40…70 °C
     
    operating altitude
    <= 1000 m without derating
    1000...4800 m with current derating 1 % per 100 m
     
    environmental characteristic
    Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
    Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
     
    standards
    UL 508C
    EN/IEC 61800-3
    Environment 1 category C2 EN/IEC 61800-3
    Environment 2 category C3 EN/IEC 61800-3
    EN/IEC 61800-5-1
    IEC 61000-3-12
    IEC 60721-3
    IEC 61508
    IEC 13849-1
     
    product certifications
    DNV-GL
    UL
    CSA
    ATEX zone 2/22
    REACH
    TÜV
    ATEX INERIS
     
    marking
    CE
     
    Packing Units
    Unit Type of Package 1
    PCE
     
    Number of Units in Package 1
    1
     
    Package 1 Weight
    17.851 kg
     
    Package 1 Height
    26 cm
     
    Package 1 width
    34 cm
     
    Package 1 Length
    74 cm
     
    Unit Type of Package 2
    P06
     
    Number of Units in Package 2
    4
     
    Package 2 Weight
    84.404 kg
     
    Package 2 Height
    86 cm
     
    Package 2 width
    60 cm
     
    Package 2 Length
    80 cm
     
    Offer Sustainability
    Sustainable offer status
    Green Premium product
     
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
     
    Mercury free
    Yes
     
    RoHS exemption information  
    China RoHS Regulation  
    Environmental Disclosure  
    Circularity Profile  
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

  • Reviews ()