TM200C40R
Price upon request
-
Product is not available
-
Additional Information
Main range of product Easy Modicon M200product or component type Logic controller[Us] rated supply voltage 100...240 V ACdiscrete I/O number 40discrete input number I2...I5: 4 fast input
I0, I1, I6, I7: 4 high speed input
I8...I23: 16 regular inputdiscrete output number 16 relaydiscrete input voltage 24 Vdiscrete input voltage type DCdiscrete input current 7 mA for inputdiscrete input logic Sink or source (positive/negative) type 1 conforming to EN/IEC 61131-2discrete output voltage 24 V DC
220 V ACdiscrete output current 2 Adiscrete output type Relay normally openpower consumption in VA 59…69 VA at 100...240 V AC (with max I/O)Complementary maximum number of I/O expansion module 4 with 128 discrete output(s) for transistor output
4 with 80 discrete output(s) for relay outputsupply voltage limits 85…264 Vnetwork frequency 50/60 Hzinrush current 50 Avoltage state 1 guaranteed >= 15 V for inputvoltage state 0 guaranteed <= 5 V for inputinput impedance 3.3 kOhm for discrete inputresponse time 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input
5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input
100 µs turn-off, I2...I5 terminal(s) for fast input
35 µs turn-on, I2...I5 terminal(s) for fast input
100 µs turn-off, I8...I13 terminal(s) for regular input
35 µs turn-on, I8...I13 terminal(s) for regular input
10 ms turn-off, Q0...Q15 terminal(s) for relay output
10 ms turn-on, Q0...Q15 terminal(s) for relay output
125 µs turn-off, I14...I23 terminal(s) for regular input
55 µs turn-on, I14...I23 terminal(s) for regular inputconfigurable filtering time 0 ms for input
3 ms for input
12 ms for inputoutput voltage limits 30 V DC
250 V ACmaximum current per output common 4 A at COM 2
4 A at COM 0
4 A at COM 1
4 A at COM 3electrical durability 100000 cycles AC-12, 240 V, 480 VA, resistive
100000 cycles DC-12, 24 V, 48 W, resistiveswitching frequency 0.1 Hz with maximum loadmechanical durability 20000000 cycles for relay outputminimum load 10 mA at 5 V DC for relay outputmemory capacity 512 byte internal flash for backup of programsdata storage equipment 32 GB micro SD card (optional)battery type BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s)backup time 3 years at 25 °C (by interruption of power supply)execution time for 1 KInstruction 0.3 ms for event and periodic taskexecution time per instruction 0.2 µs Booleanexct time for event task 60 µs response timeclock drift <= 90 s/month at 25 °Cregulation loop Adjustable PID regulator up to 14 simultaneous loopscontrol signal type Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode)
Pulse/direction at 100 kHz for fast input (HSC mode)
Single phase at 100 kHz for fast input (HSC mode)
CW/CCW at 100 kHz for fast input (HSC mode)counting input number 4 fast input (HSC mode) at 100 kHz 32 bitsintegrated connection type USB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with terminal block connector and RS485 interface
Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface
Isolated serial link serial 2 with terminal block connector and RS485 interfacetransmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
12 Mbit/s for USBcommunication port protocol USB port: USB - SoMachine-Network
Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Networklocal signalling 1 LED (green)PWR:
1 LED (green)RUN:
1 LED (red)module error (ERR):
1 LED (green)SD card access (SD):
1 LED (red)BAT:
1 LED (green)SL1:
1 LED per channel (green)I/O state:electrical connection Mini B USB 2.0 connectorfor a programming terminal
removable screw terminal blockfor inputs
removable screw terminal blockfor outputs
removable screw terminal block, 4 terminal(s) for connecting the serial link1
removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supplymaximum cable distance between devices Unshielded cable: <50 m for input
Shielded cable: <10 m for fast input
Shielded cable: <10 m for high speed input
Unshielded cable: <150 m for outputinsulation Non-insulated between inputs
Between output and internal logic at 1780 V AC
Between output groups at 1780 V AC
Between supply and internal logic at 1780 V AC
Between input and internal logic at 500 V AC
Between fast input and internal logic at 500 V AC
Between input groups at 500 V ACsensor power supply 24 V DC at 300 mA supplied by the controllermarking CEmounting support Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715height 90 mmdepth 70 mmwidth 175 mmnet weight 0.504 kgEnvironment IP degree of protection IP20 with protective cover in placeproduct certifications IACS E10
CULus
RCM
CSAstandards EN/IEC 61010-2-201
EN/IEC 61131-2electromagnetic compatibility Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to EN/IEC 61000-4-3
Magnetic field at power frequency - test level: 30 A/m conforming to EN/IEC 61000-4-8
Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 0.5 kV (power lines (DC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (AC)) conforming to EN/IEC 61000-4-5
Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
Conducted emission - test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011
Conducted emission - test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011
Radiated emission - test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011
Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011shock resistance 15 gn for 11 ms
30 gn for 6 msimmunity to microbreaks 10 msvibration resistance 3.5 mm at 5…8.4 Hz on symmetrical rail
1 gn at 8.4…150 Hz on symmetrical rail
3.5 mm at 5…8.7 Hz on panel mounting
2 gn at 8.7…150 Hz on panel mountingrelative humidity 10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)ambient air temperature for operation 0…55 °C (horizontal installation)ambient air temperature for storage -25…70 °Cpollution degree <= 2operating altitude 0...2000 mstorage altitude 0…3000 mPacking Units Package 1 Weight 7.400 kgPackage 1 Height 9.000 cmPackage 1 width 18.400 cmPackage 1 Length 13.800 cmOffer Sustainability Sustainable offer status Green Premium productEU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins -
Reviews ()
Write a Review