Logic Controller M262, 3ns/instruction, Ethernet
-
Additional Information
Main range of product Logic/motion controller - Modicon M262product or component type Logic controller[Us] rated supply voltage 24 V DC - 15...20 %discrete input number 4, discrete input fast input conforming to IEC 61131-2 Type 1discrete output type Transistordiscrete output number 4 transistor fast outputdiscrete output voltage 24 V DCdiscrete I/O number 8communication port protocol Ethernet IP/Modbus TCP
Serial link
Modbus RTU and ASCII
HTTP
HTTPSComplementary overvoltage protection Withdiscrete output current 0.5 A for transistor output (Q0...Q3)
0.5 A for fast output (Q0...Q3)maximum number of I/O expansion module 7 (remote)
7 (local)supply voltage limits 20.4…28.8 V DCinrush current 40 APLC Power Consumption 82 Wdiscrete input logic Sink or sourcediscrete input voltage 24 Vdiscrete input voltage type DCvoltage state 1 guaranteed >= 15 V for DCvoltage state 0 guaranteed <= 5 V for DCdiscrete input current 7.5 mA for input
7.5 mA for fast inputinput impedance 2.81 kOhm for inputresponse time <= 1 µs turn-on, I0...I3 terminal(s) for fast input
<= 1 µs turn-off, I0...I3 terminal(s) for fast input
<= 1 µs turn-on, Q0...Q3 terminal(s) for fast output
<= 1 µs turn-off, Q0...Q3 terminal(s) for fast outputconfigurable filtering time 0.5 ms for fast input
0.01 ms for fast input
0.002 ms for fast input
1 ms for fast input
4 ms for fast input
0.1 ms for fast input
0.05 ms for fast input
0.005 ms for fast input
0.001 ms for fast input
12 ms for fast inputdiscrete output logic Sourceoutput voltage limits 30 V DCmaximum current per output common 0.5 A with Q0...Q3 for fast outputmaximum output frequency 300 kHzaccuracy +/- 0.1 % at 0.02…0.1 kHz for fast output
+/- 1 % at 0.1…1 kHz for fast outputmaximum leakage current 10 µA for outputmaximum tungsten load <1.5 Wprotection type Short-circuit and overload protection with automatic reset
Reverse polarity protection
Short-circuit protectionreset time 200 ms automatic reset fast outputmemory capacity 32 MB for program RAM
32 MB for OS/website RAM
192 MB for system memory RAMdata backed up 1 GB built-in flash memory for backup of user programsdata storage equipment <= 32 GB SDHC card (optional)backup time 1000 h at 25 °Cexecution time for 1 KInstruction 0.005 msapplication structure 8 event tasks
4 cyclic master tasks
3 cyclic master tasks + 1 freewheeling task
8 external event tasksrealtime clock Withclock drift <= 10 s/month
<= 10 s/month at 25 °Cpositioning functions Libraries axes coordinated functionintegrated connection type USB type mini B
EtherNet port1 Ethernet 1 with RJ45 connector
EtherNet port2 / switch Ethernet 2 with 2 RJ45 connector
Serial link with RJ45 connectortransmission rate 115 kbit/s for RS485
115 kbit/s for bus length of 15 m for RS485
115 kbit/s for bus length of 3 m for RS232
480 Mbit/s for bus length of 3 m for USB
10/100 Mbit/s for Ethernet1
115 kbit/s for RS232
1 Gbit/s for Ethernet2
480 Mbit/s for USB
10/100 Mbit/s
1 Gbit/scommunication service Ethernet/IP adapter
DHCP client
IEC VAR ACCESS
Modbus TCP client
Modbus TCP server
SNMP client/server
FTP client/server
SQL client
Send and receive email from the controller based on TCP/UDP library
Web server
OPC UA server
DNS client
Web visu
Ethernet RSTP
MQTTlocal signalling 1 LED (green/red)PWR:
1 LED (green/red)RUN:
1 LED (green/red)ERROR (fault):
1 LED (green/red)stop forced:
1 LED (green/red)I/O error (I/O):
1 LED (green/orange)Sd card activity:
1 LED (green/orange)SL activity:
1 LED (green/red)ETH1 state:
1 LED (green/red)ETH2 state:
1 LED (green/red)EIP MS:
1 LED (green/red)EIP NS:electrical connection removable spring terminal block
removable spring terminal blockfor connecting the 24 V DC power supplymaximum cable distance between devices Shielded cable: <3 m for fast input
Shielded cable: <3 m for fast output
Unshielded cable: <50 m for input
Unshielded cable: <50 m for outputinsulation Between fast input and internal logic at 550 V AC
Non-insulated between inputs
Between output and internal logic at 500 V AC
Between fast output and internal logic at 500 V AC
Non-insulated between outputs
Between input and output at 500 V AC
Between supply and internal logic at 500 V AC
Non-insulated between supply and groundsurge withstand 1 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
1 kV shielded cable common mode conforming to EN/IEC 61000-4-5
0.5 kV relay output differential mode conforming to EN/IEC 61000-4-5
1 kV input common mode conforming to EN/IEC 61000-4-5
1 kV transistor output common mode conforming to EN/IEC 61000-4-5maximum number of connections 64 Ethernet/IP device
64 Modbus TCP device
96mounting support Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kitheight 100 mmdepth 90 mmwidth 125 mmnet weight 0.655 kgEnvironment standards UL 61010-1
UL 61010-2-201
CSA C22.2 No 61010-1
CSA C22.2 No 61010-2-201
CSA C22.2 No 213
ANSI/ISA 12-12-01
EN 61131-2product certifications CE
CULus
RCM
EAC
Achillesresistance to electrostatic discharge 4 kV on contact conforming to EN/IEC 61000-4-2
8 kV on air conforming to EN/IEC 61000-4-2resistance to electromagnetic fields 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3resistance to fast transients 2 kV (power lines) conforming to EN/IEC 61000-4-4
1 kV (Ethernet line) conforming to EN/IEC 61000-4-4
1 kV (serial link) conforming to EN/IEC 61000-4-4
1 kV (input) conforming to EN/IEC 61000-4-4
1 kV (transistor output) conforming to EN/IEC 61000-4-4resistance to conducted disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-4
3 V 0.1...80 MHz
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)electromagnetic emission Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011
Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011
Radiated emissions - test level: 40 dBµV/m at 30…230 kHz conforming to EN/IEC 55011
Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011
Radiated emissions at 230…1000 MHz conforming to EN/IEC 55011immunity to microbreaks 0.01 msambient air temperature for operation -20…60 °C (horizontal installation)
-20…50 °C (vertical installation)
-20…45 °C (flat mounting)ambient air temperature for storage -40…85 °Crelative humidity 10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)IP degree of protection IP20pollution degree 2operating altitude 0...2000 mstorage altitude 0…3000 mvibration resistance 3.5 mm at 2…8.4 Hz on symmetrical rail
1 gn at 8.4…200 Hz on symmetrical rail
3.5 mm at 2…8.4 Hz on panel mounting
1 gn at 8.4…200 Hz on panel mountingshock resistance 15 gn for 11 msPacking Units Package 1 Weight 0.600 kgPackage 1 Height 1.000 dmPackage 1 width 0.900 dmPackage 1 Length 1.250 dmOffer Sustainability Sustainable offer status Green Premium productEU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsPVC free Yes -