XY2SB714

SKU:XY2SB714

Price upon request
  • Product is not available

-
+

Minimum Order Quantity1

Accept Small Orders No

2-hand control station + pedestal - 2 pushbuttons+1 Emergency Stop mushroom head
  • Additional Information

    Main
    range of product
    Preventa XY2
     
    product or component type
    Two-hand control station and pedestal
     
    component name
    XY2S
     
    control station composition
    2 push-buttons + 1 emergency stop push-button
     
    control button type
    1 push-button, mushroom, red, 1 NC + 1 NC simultaneous
    2 push-buttons
     
    Complementary
    housing colour
    Orange RAL 2008
     
    surface finish
    Painted
     
    cable entry
    1 plain hole for M25
    2 plain holes for M20
     
    mechanical durability
    1000000 cycles
     
    contact code designation
    A600 AC-15, Ue = 240 V, Ie = 3 A
    Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A
     
    [Ui] rated insulation voltage
    600 V (pollution degree 3) conforming to EN/IEC 60947-1
    600 V conforming to UL 508
    600 V conforming to CSA C22.2 No 14
     
    [Uimp] rated impulse withstand voltage
    6 kV EN/IEC 60947-1
     
    positive opening
    With conforming to EN/IEC 60947-5-1 appendix K
     
    short-circuit protection
    10 A gG cartridge fuse protection conforming to EN/IEC 60269
     
    electrical durability
    1000000 cycles utilisation category AC-15, operating rate <60 cyc/mn at 120 V, 3 A, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
    1000000 cycles utilisation category AC-15, operating rate <60 cyc/mn at 230 V, 2 A, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
    1000000 cycles utilisation category AC-15, operating rate <60 cyc/mn at 24 V, 4 A, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
    1000000 cycles utilisation category DC-13, operating rate <60 cyc/mn at 110 V, 0.2 A, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
    1000000 cycles utilisation category DC-13, operating rate <60 cyc/mn at 24 V, 0.5 A, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
     
    electrical reliability
    Failure rate < 0.00000001 at 17 V, 0.005 A conforming to EN/IEC 60947-5-4
    Failure rate < 0.000001 at 5 V, 0.001 A conforming to EN/IEC 60947-5-4
     
    net weight
    17 kg
     
    Environment
    standards
    EN 574
    EN 954
     
    protective treatment
    TC
     
    ambient air temperature for operation
    -25…70 °C
     
    ambient air temperature for storage
    -40…70 °C
     
    vibration resistance
    5 gn (f= 2…500 Hz) conforming to EN/IEC 60068-2-6
     
    shock resistance
    10 gn for 11 ms conforming to EN/IEC 60068-2-27
     
    electrical shock protection class
    Class I conforming to EN/IEC 61140
     
    IP degree of protection
    IP65 conforming to EN/IEC 60529
     
    Packing Units
    Unit Type of Package 1
    PCE
     
    Number of Units in Package 1
    1
     
    Package 1 Weight
    18.755 kg
     
    Package 1 Height
    37.5 cm
     
    Package 1 width
    46 cm
     
    Package 1 Length
    76.5 cm
     
    Offer Sustainability
    Sustainable offer status
    Green Premium product
     
    REACh Regulation  
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
     
    Mercury free
    Yes
     
    RoHS exemption information  
    China RoHS Regulation  
    Environmental Disclosure  
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
     
    Contractual warranty
    Warranty
    18 months